Retail
Check the four discharge directions of the square louver face against the lighting tracks and the tops of the shelves.
A square diffuser between two lighting tracks above a shop display table and checkout counter. Orange lines show the four-way diffuser supplying the shop floor between the displays. A close-up shows the louver core pulling out of the flat flange and sliding back into place.
Moving a display can put a tall shelf in the path of a ceiling diffuser. Lay the lighting plan over the current and proposed shelf layouts before choosing which way each outlet blows.
Design decisions
- Choose a pattern for each display bay
- A four-way face sends air toward all four sides of an open bay. Where tall shelving flanks a long aisle, compare a two-way face aimed along its length. Mark shelf heights and the drop of hanging signs so the supplier can check both layouts.
- Check how far the air travels
- Measure from each outlet to the wall or halfway to the next outlet in each discharge direction. Ask for throw, the distance air travels before slowing to a stated speed, at the scheduled airflow. Compare both minimum and full flow if the store varies its air volume.
- Leave room to remove the core
- Show where a technician can set a ladder after the store is stocked. For a removable louver face, check how the core releases and lowers past track lights and hanging signs. Confirm that the quoted size comes with a removable core.
Product selection
4-way Louver Face Square Diffusers (Standard Flat Flange)The fixed four-way pattern suits an open display bay with room for air to travel on all sides. Match the standard flat flange and finish to the approved ceiling detail.
2-way Louver Face Square Diffusers (Opposite Style)Two opposite discharge paths can follow a straight aisle between tall displays. Mark their orientation on the order so the installer can align the core with the shelves.
Inquiry brief
Include these details when you request a quote.
- Ceiling and merchandising plans with current and proposed shelf positions, heights, lighting tracks, and hanging signs.
- Mounting height and distance to walls and adjacent outlets in ft or m, with arrows showing each discharge direction.
- Design and minimum occupied airflow per outlet in cfm or L/s, with the air speed used for the specified throw.
- Quantities by pattern, neck dimensions in inches or mm, ceiling detail, finish sample, and clearance for core removal.
Industry references
ASHRAE Handbook sections may require a subscription.
